Durawise Industry Services

Durawise Industry ServicesDurawise Industry ServicesDurawise Industry ServicesDurawise Industry Services
  • Home
  • Solutions
  • Service Area
  • FAQs
  • About Us
  • Contact Us
  • Blog
  • Sign In
  • Create Account

  • Bookings
  • My Account
  • Signed in as:

  • filler@godaddy.com


  • Bookings
  • My Account
  • Sign out

Ask about our Spring 2022 savings offer!

Durawise Industry Services

Durawise Industry ServicesDurawise Industry ServicesDurawise Industry Services

Signed in as:

filler@godaddy.com

  • Home
  • Solutions
  • Service Area
  • FAQs
  • About Us
  • Contact Us
  • Blog

Account


  • Bookings
  • My Account
  • Sign out


  • Sign In
  • Bookings
  • My Account

Welcome Valued pool contractors

Thank You FOR YOUR CONSIDERATION IN OUR TEAM

This page is exclusively for our authorized valued contractors only. If you are not listed as valued contractor projects submitted will not be serviced. 

Need to Place a Quote or an Order?

You must be on an approved contractor list with Durawise Ind
Valued Client Quick Order FormLeak Testing Estimate Request FormRepair Estimate and Order FormRefer a Client Direct to DWISPost Build/Reno Leak Estimate Form

basic leak detection package

Observation Report

 This "Observation Report" is for informational purposes only. The “Observation Report” may not depict accurate size, scale, nor locations. It is based on approximate locations only. All pipe locates below grade are based on equipment readings, and sound. Please note this is not an inspection report. 

Pressure Test

 A "Pressure Test" is used to check your pipe’s ability to hold a defined amount of pressure for the time depicted. In this case, it is used to check for active leaks or breaks in the pipe run that is allowing your water to escape. Heaters, air raters, filters and other equipment are not pressure tested; Meaning pressure tests are used to check for leaks at underground piping. Typically, a pressure test will be from the nearest connection point before the pipe goes underground to a pool side inlet/ outlet.  

A) Zone: Pressure tests are broken into Zones. "Zone" meaning what was included in a particular pressure test between point locations specified. Different pipe runs (example: spa floor water feature vs. pool returns), may be combined in one "Zone" due to equipment construction or for time constraints. A "Zone" is decided on a case by case basis. Depending on the length of a Zone, Durawise Industry Services will hold a pressure test for 1-10 minutes. An example of a shorter time one (1) minute would be skimmer to pool, with a pipe run of less than 3'-0".  

B) Plugs: A pressure test relies on a good plug seal. A plug may not seal properly because of blistering/bubbling, fitting construction, previous repairs, and other instances. This forces leak detectors to use extensions, inflatables and other products to perform pressure tests. All fittings in these instances will be dye tested; however, ground water and debris can affect dye pull. See "Perceptibility Testing" below.  

1) Water Features: Water features, such as shear descents and rock features are typically not constructed to allow for proper pressure testing. Due to these reasons, water features are typically not pressure tested. The exterior of the water features will be checked for water-loss. A customer may opt for a more in-depth/invasive test at additional charge. 

2) Equipment Construction: Equipment may not be constructed to allow for a pressure test. In these cases, client will be provided options to allow for testing. Options could be cutting, taps, and other methods; however, options will be an additional charge that will be disclosed at the time of the leak detection. 

3) Please note, pools that have not been running, lines that have been dormant, empty pools, pools with debris, and leaves can obstruct a pressure test. Drought seasons can highten the change of a false pressure test on empty pools and dormant lines. 

Locates

 The term "Locates" is a reference to breaks in pipes that are underground and can not be seen from the surface. Durawise Industry Services has three (3) pieces of equipment (manufactured by others) to help narrow down leak locations; however, ground water, hollowed ground under decks, other underground utilities/pipes, and surrounding noise pollution can affect the results of a location. For these reasons Durawise Industry Services notates "Locates" with one of three symbols: 

1) "  "Narrowed Break Locate" this means the devices have picked up a break and the location has been identified in the general location. A pressure test at time of repair is required to verify there are no other breaks with in the Zone. (Typical) 

2) " "Tentative Break Locate" this means the leak detector has reason to believe there maybe a break within this location that cannot be confirmed or has reason to believe a second break within a "Zone" based on noises picked up. The leak detector will notate specific reasons for use of this symbol and in most cases provide a plan of action. (Rare Instances) 

3) " " Impeded Break Locate" this means the leak detector cannot pinpoint a leak into a general location. This can be due to echoing, surrounding drainage, hollowed decks and other issues. The leak detector will notate issues. In order to find the break, an additional price may need to be charged, because multiple holes may need to be cut into deck. (Rare Instances).  

****Please note: Air and water takes the least path of resistance. This means more than one break can be on any "Zone". Therefore, at the time of repair or after the repair an additional pressure test is recommended. This is at an additional charge. Change orders may be requested to pinpoint "Tentative Break Locate" and/or "Impeded Break Locates".  

Perceptibility Test

The "Perceptibility Tests"  is the use of dye to detect areas within the bow of th gunite strucutre to escape.  Dye is used to observe underwater movement. Dye tests can be impeded by debris, low water-level, ground water and other issues. Some items may not pull dye one day and start taking on water later. (An example of this on multiple projects is the drain housing. After a heavy rain, customers have reported they lost less water or did not notice loss at all. About a week or so after the rain stopped, the loss started again. Irrigation and other active leaks within the pool can obstruct a dye test.   

Equipment leaks

The equipment pad will be checked for visible water leaks while the system is running. This is based on accessibility. This does not include air leaks. If an air leak is identified within a Zone, it will be notated.  

water monitoring

Water monitoring is not included in this package. See add costs.  Please note water monitoring cannot be performed in excessive heat, windy days for features, nor when there is chance of rain. Durawise Industry Services will need to have access to controls outside of items not programmed to run on service. Otherwise, monitoring will be limited. 

Warranty

 Warranty: Due to the nature of service, all leak detections are performed on a best effort basis and based on observations of conditions taken on the date/time of service. For these reasons, a fourteen (14) day leak detection warranty from the date of the leak detection, this date ___TBD_______, has been provided. If required, this leak detection warranty provides an additional leak detection by Durawise Industry Services only. It does not include costs for repairs, nor other costs. During your leak detection warranty period, the customer and/or their clients will need to monitor the pool/spa/basin's water-levels. This can be done with a simple bucket test. If you need to know how to perform a bucket test, please search "Swimming Pool Bucket Test" online, or contact Durawise Industry Services by email at sales@durawiseindustryservices.com. 

Specialty Construction and Features

Water Monitoring is an additional charge. It is only available on request. 


Certain construction and features are not included in the full leak detection package mentioned above. This includes but is not limited to: In-Floor Returns/ In-Floor Valve Sytems, rock water features, shear descents, statue fountains, other types of fountains, cannisters, paramount systems and similar construction will be an additional charge. Please let us know if your project contains these fitting, fixtures or construction. 

Ordering

The ordering and booking form is based on the information provided on this page. The prices are estimates only, based on previous experience. Each site is different and cost changes may be requested. None of the booking options include "Specialty Construction and Features".  By using this site you agree to keep this information confidential, and not disclose information within this page, nor share prices with any entity, company, nor individual. All service prices are based on times provided within service. Additional work and or scope will result in additonal charges. 


DWIS reserves the right to revise pricing and removing booking services at any time. 


Please keep in mind additional services will be added soon. If you don't see your services, complete forms to be given a date. 



Durawise Industry Services - All Rights Reserved.

  • Premier Contractors
  • Valued Contractors
  • Privacy Policy
  • Disclaimer

Welcome!

Thank you for your interest in Durawise Industry Services. Your one stop shop for all your swimming pool leak detection needs.

Get Started